Product Feature
Product Type: Three-phase multifunctional protector
Input Voltage Range: AC 80-300V
Over-Voltage Protection Value: 120-300V (default: 270V)
Over-Voltage Recovery Value: 115-295V (default: 265V)
Under-Voltage Protection Value: 80-210V (default: 170V)
Under-Voltage Recovery Value: 85-215V (default: 175V)
Over-Current Protection Value: 1-63A (default: 40A)
Over-Current Recovery Value: 0.5-62.5A
Temperature Protection Value: 0-100°C (default: 80°C)
Temperature Recovery Value: 5-95°C (default: 80°C)
Leakage Protection Value: 10-300mA (default: 30mA)
Power Overload Protection Value: 0.1-70kW (default: 20kW)
Protection Action Time: 1-30s (default: 1s)
Recovery Delay Time: 1-999s (default: 30s)
Power-On Delay Time: 0-999s (default: 10s)
Display Interval Delay Time: 1-30s (default: 10s)
Screen Bright Time: 1-60s (default: 10s)
Continuous Fault Count (Over-current/Power Overload/Leakage): 1-20 times (default: OFF)
Modbus RTU Communication Format: n.8.1 / o.8.1 / e.8.1
Modbus RTU Baud Rate: 300/600/1200/2400/4800/9600/19200 bps
Modbus RTU Communication Address: 1-247 (default: 1)
Power Consumption: ≤2W
Electrical & Mechanical Life: ≥100,000 cycles
Electrical and mechanical life:≥100000cycles