Opis
TOCT1 house hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V .Rated operating voltage in AC-7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC-7b usage , rated current to 10A. Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.
Uporaba: za dom, stanovanje, hotel, samodejni izklop ali priključitev napajanja.
Normalni delovni in montažni pogoji:
1. Ambient temperature:-5??C to +40??C,the average temperature no more than +35??C in 24 hours.
2. Nadmorska višina: največ 2000 m.
3. Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40??C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25??C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.
4. Razred onesnaženosti: razred 2.
5. Pogoj namestitve: razred II.
Navodila za uporabo
1. Pred namestitvijo preverite, ali kontaktor ustreza obsegu uporabe in delovnim pogojem.
2. Med namestitvijo povlecite komponento za zaustavitev gibanja navzdol in namestite kontaktor v varno orbito, nato pa komponento za zaustavitev gibanja potisnite navzgor, da jo pritrdite na varno orbito in se izognete zrahljanja in padcu. Če želite odstraniti kontaktor, komponento za zaustavitev gibanja povlecite navzdol.
Opozorilo
a). Prepričajte se, da je način povezave pravilen
b). Med priklopom privijte pritrdilni vijak























Mnenja
Obstaja še ni komentarja.