баяндоо
баяндоо
TORT7-M1 10 in 1 Multi-function time relay
1. Жалпы
TORT7-M1 is a versatile solution for controlling electrical appliances, lighting, heating, motors, pumps, and fans. It offers 10 timing functions and 10 adjustable time ranges, from 0.1 seconds to 10 days, all easily set via user-friendly rotary switches. Supporting multi-voltage applications, this compact DIN rail module provides reliable automation with a clear LED status indicator for seamless integration into various control systems.
2. Техникалык маалыматтар
Model: TORT7-M1
милдеттери:
- 5 time functions controlled by supply voltage
- 4 time functions controlled by control input
- 1 function of latching relay
Чыңалуу диапазону: AC230V (50/60Hz)
Кубат киргизүү: AC макс.6VA/1.3W
Берүү чыңалуусунун толеранттуулугу: -15%; +10%
Убакыт диапазондору: 0.1s-10days, ON, OFF
Убакытты жөндөө: Потенциал өлчөгүч
Убакыттын четтөөсү: 10% -механикалык жөндөө
Кайталоо тактыгы: 0.2% белгиленген маанинин туруктуулугу
Температура коэффициенти: 0.05%/C, = 20°C (0.05%, = 68℉)
Чыгаруу: 1xSPDT
Учурдагы рейтинг: 16A/AC1
Которуштуруу чыңалуу: 250VAC
Мин. сындыруу кубаттуулугу DC: 500 мВт
Камсыздоо көрсөткүчү: жашыл LED
Чыгаруу көрсөткүчү: кызыл LED
Механикалык иштөө мөөнөтү: 1 × 107
Электрдик иштөө мөөнөтү: 1 × 105
Баштапкы абалга келтирүү убактысы: макс.200мс
Иштөө температурасы: -20℃ дан +55℃ га чейин
Сактоо температурасы: -35°C дан +75°C га чейин
Монтаждоо/DIN темир жол: Дин темир жол EN/IEC 60715
Коргоо даражасы: алдыңкы панель/IP20 терминалдары үчүн IP40
Иштөө позициясы: каалаган
Ашыкча чыңалуу категориясы: III.
Булгануу даражасы: 2
Максималдуу кабелдин өлчөмү (мм2): катуу зым макс.1 × 2.5 же 2 × 1.5 / жең менен макс.1 × 2.5 (AWG 12)
Тартуу моменти: 0.4Nm
Өлчөмдөрү: 90x18x64мм
Standards: EN 61812-1,EC60947-5-1
3.Функциянын өзгөчөлүктөрү
A:On Delay (Power On)
When the input voltage U is applied, timing delay t begins. Relay contacts R change state after time delay is complete. Contacts R return to their shelf state when input voltage U is removed. Trigger switch is not used in this function.
B:Interval(Power On)
When input voltage U is applied, relay contacts R change state immediately and timing cycle begins. When time delay is complete, contacts return to shelf state, When input voltage U is removed contacts will also return to their shelf state.Trigger switch is not used in this function.
C:Repeat Cycle (Starting Off)
When input voltage U is applied, lime delay t begins. When time delay t is complete, relay contacts R change state for time delay t. This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function.
D:Repeat Cycle (Starting On)
When input voltage U is applied, relay contacts R change state immediately and time delay t begins.When time delay t is complete, contacts return to their shelf state for time delay t, This cycle will repeat until input voltage U is removed, Trigger switch is not used in this function.
E:Off Delay (S Break)
Input voltage U must be applied continuously, When trigger switch S is closed, relay contacts R change state, When trigger switch S is opened, delay t begins, when delay t is complete, contacts R return to their shelf state.If trigger switch S is closed before time delay t is complete, then time is reset, When trigger switch S is opened, the delay begins again, and relay contacts R remain in their energized state, lf input voltage U is removed.relay contacts R return to their shelf state.
F:Single Shot
Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. During time-out, the trigger signal S is ignored, The relay resets by applying the trigger switch S when the relay is not energized.
G:Single Shot Trailing Edge (Non-Retriggerable)
Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. At the end of the preset time t, the relay contacts R return to their normal condition unless the trigger switch S is opened and closed prior to time out t (before preset time elapses). Continuous cycling of the trigger switch S at a rate faster than the preset time will cause the relay contacts R to remain closed. lf input voltage U is removed, relay contacts R return to their shelf state.
H:On/Off Delay
Input voltage U must be applied continuously. When trigger switch S is closed, time delay t begins. When time delay t is complete, relay contacts R change state and remain transferred until trigger switch S is opened.If input voltage U is removed, relay contacts R return to their shelf state
Note:To ensure reliable operation, install this electrical device in a standard cabinet away from interference sources, using protective measures and verifying system compatibility.
I:Latching relay
Input voltage U must be applied continuously. Output changes state with every trigger switch S closure. lf input voltage U is removed,relay contacts R return to their shelf state.
J:Pulse generator
Upon application of input voltage U, a single output pulse of 0.5 seconds is delivered to relay after time delay t. Power must be removed and re-applied to repeat pulse. Trigger switch is not used in this function.

















сын-пикир
бирок эч кандай сын-пикирлер да бар.