TOCT1 house hold AC contactor is mainly designed for AC 50Hz or 60Hz circuits with 230V .Rated operating voltage in AC-7a usage ,rated operating voltage up to 230V, rated operating current up to 25A, Rated operating voltage in AC-7b usage , rated current to 10A. Using in breaking capacity below 6kA circuit. For distance connect or break the circuit.
Sovellus: kotiin, asuntoon, hotelliin, automaattinen katkaisu tai virran kytkeminen.
Normaalit käyttö- ja asennusolosuhteet:
1. Ambient temperature:-5??C to +40??C,the average temperature no more than +35??C in 24 hours.
2. Korkeus: enintään 2000 m.
3. Atmospheric conditions: the relative humidity of the installation place should be no more than 50% when the maximum temperature is +40??C:if under a lower temperature,a higher relative humidity is allowed. The monthly average minimum temperature in the wettest month should not exceed +25??C and the monthly average maximum relative humidity of this month no more than 90%.Besides,the dew on the surface of products caused by temperature change should be taken into consideration.
4. Saasteluokka: luokka 2.
5. Asennusolosuhteet: luokka II.
Hakemusohjeet
1. Tarkista ennen asennusta, onko kontaktori samaa mieltä käyttötarkoituksesta ja käyttöolosuhteista.
2. Asennuksen aikana vedä liikkeenpysäytyskomponentti alas ja aseta kontaktori turvalliselle kiertoradalle. Työnnä sitten liikkeenpysäytyskomponenttia ylös kiinnittääksesi kontaktorin turvalliselle kiertoradalle. Vältä löystymistä ja pudottamista. Vedä liikkeenpysäytyskomponentti alas, jos haluat irrottaa kontaktorin.
varovaisuus
a). Varmista, että yhteystapa on oikea.
b). Kierrä kiinnitysruuvi kiinni liitännän aikana.